BLJYP - RESIN RP 1700-1

Product Identification

Product ID:RESIN RP 1700-1
MSDS Date:12/10/1988
FSC:8040
NIIN:01-046-5056
Kit Part:Y
MSDS Number: BLJYP

Responsible Party
CIBA-GEIGY CORP REN PLASTICS DIV
4917 DAWN AVE
EAST LANSING, MI 48823-5605
US

Emergency Phone: 517-351-5900

Info Phone: 517-351-5900 / FAX 517-351-9003

Preparer: PETER HENIGE

Cage: 02684

Contractor
CIBA SPECIALTY CHEMICALS CORPORATION
EAST LANSING, MI 48823-5691 US

Telephone: 517-351-5900

Cage: 02684

Ingredients

PARATERTIARY BUTYSPHNYL GLYCIDYL ETHER (REACTIVE DILVENT)

CAS: 3101-60-8

RTECS: TX4250000


FUMED SILICA

CAS: 112945-52-5

RTECS: VV7310000

OSHA PEL 20 MPPCF

ACGIH TLV: 5 MG/M3 RESP DUST; *


DIGLYCIDYL ETHER OF BISPHENOL A (EPOXY RESIN)

CAS: 25068-38-6


C12 AND C14 ALKYL GLYCIDYL ETHERS (EPOXIDE 8)

CAS: 68609-97-2

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITANT. EYE: IRRITANT.
SENSITIZATION: POSSIBLE IN SUSCEPTIBLE INDIVIDUALS.
Medical Cond Aggravated by Exposure:SKIN AND EYE CONDITIONS.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH EYES W/WATER-15 MIN. CALL PHYSICIAN.
SKIN: WASH W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER
BEFORE RE-USE. INGESTION: IF CONSCIOUS, GIVE PLENTY OF WATER. DO
NOT INDU CE VOMITING. CALL PHYSICIAN. INHALATION: REMOVE TO FRESH
AIR. GIVE OXYGEN &/OR CPR IF NEEDED. CALL PHYSICIAN. REFERRAL TO
PHYSICIAN IS RECOMMENDED IF THERE IS ANY QUESTION ABOUT SERIOUSNESS
OF INJURY.

Fire Fighting

Flash Point:>340F,>171C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:REMOVE SPILLAGE BY ABSORBING IN ABSORBENT
MATERIAL.

Handling

Handling and Storage Precautions:WARNING! CAUSES SKIN & EYE IRRITATION.
MAY CAUSE ALLERGIC SKIN REACTION. AVOID CONTACT W/EYES, SKIN &
CLOTHING.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN.
NUISANCE DUST MAY BE GENERATED WHEN SANDING OR SAWING CURED
MATERIAL.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR WHEN VAPOR/MIST EXPOSURE IS LIKELY.
Ventilation:GENERAL MECHANICAL AND LOCAL EXHAUST IN ACCORDANCE WITH
ACGIH RECOMMENDATIONS.
Protective Gloves:WEAR IMPERMEABLE GLOVES.
Eye Protection:WEAR SPLASH-PROOF CHEMICAL GOGGLES.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
KEY1;T6.

Chemical Properties

HCC:V5
Vapor Pres:.05MM@300F
Spec Gravity:1.05-1.15
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR OR SLIGHTLY HAZY AMBER LIQUID; SLIGHT ODOR.
Percent Volatiles by Volume:.6 MAX

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS AND BASES.
Stability Condition to Avoid:EXCESSIVE HEAT FOR PROLONGED PERIODS OF
TIME.
Hazardous Decomposition Products:COMBUSTION MAY FORM TOXIC MATERIALS,
SUCH AS CARBON DIOXIDE AND CARBON MONOXIDE.

Disposal

Waste Disposal Methods:CONSULT QUALIFIED LOCAL OR CORPORATE PERSONNEL
FOR METHOD THAT WILL COMPLY WITH LOCAL, STATE AND FEDERAL HEALTH
AND ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.